Cardiac Care & ICU Equipments

ECG Machines
   - 3-Channel ECG Machine
   - 6-Channel ECG Machine
   - 12-Channel ECG Machine
   - ECG Simulator

Oxygen Analyser
   - Oxygen Analyser SmartO2 830
   - Oxygen Analyser Model Oxiquant MC
Defibrillator
   - AED
   - AED Trainer
   - Biphasic Defibrillator Rescue 230
   - Biphasic Defibrillator Rescue Life

Multipara Monitor
   - 2 - Para Monitor
   - 5 - Para Monitor

   - External Sidestream ETCO2
   - Mainstream End Tidal
     CO2 Sensor

Non Invasive B.P. Monitor
Infusion Pump
   - Syringe Infusion Pump
   - Volumetric Infusion Pump
   - Portable Syringe Pump
Pulse Oximeter
   - Fingertip Pulse Oximeter
   - Handheld Pulse Oximeter
   - Tabletop Pulse Oximeter
Vascular Doppler
Holters
   - 12-Channel Holter
   - 3-Channel Holter

Connect with us:  

Contact me now: 
sales@medicalpointindia.com
medical_point 
hygeiamed@hotmail.com 
medical_point
 

POX-610 Vital Signs Monitor
can continually measure Sp02, PR at a real time. It is with compact appearance, comprehensive functions, simple and convenient operation, and widely used in hospitals, community medical treatment and family.

Features:

  1. High resolution 4.3" color LCD screen
  2. Compact and portable, allowing for uninterrupted monitoring
  3. AC power supply, with built-in lithium battery
  4. Adjustable audible and visual alarms
  5. Storage and review of patient's trend data up to 36 hours
  6. Applicable to adult, pediatric and neonatal patient
  7. Convenient and quick in inquiring measurement data
  8. USB data upload
  9. Optional: printing

Performance:
Sp02 monitoring
Continuous real-time measuring.Adopt digital Sp02 technology, which has strong
anti-interference capability.Real-time display Sp02, pulse rate, Sp02 Plethysmogram,
bar graph, Sp02 and Pulse rate(PR) trend graph.
Trend graph with the function of adaptive scaling
Standard adult finger-clip probe, binding probe for neonatal is optional.

Sp02 Measuring
Range: 35%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.

Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
Measurement Performance in Weak Filling Condition: Sp02 and pulse rate can be shown
correctly when pulse-filling ratio is 0.4%, Sp02 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darKroom is less than ±1%.