POX-610 Vital Signs Monitor

can continually measure Sp02, PR at a real time. It is with compact appearance, comprehensive functions, simple and convenient operation, and widely used in hospitals, community medical treatment and family.


Features:

  • 1. High resolution 4.3" color LCD screen
  • 2. Compact and portable, allowing for uninterrupted monitoring
  • 3. AC power supply, with built-in lithium battery
  • 4. Adjustable audible and visual alarms
  • 5. Storage and review of patient's trend data up to 36 hours
  • 6. Applicable to adult, pediatric and neonatal patient
  • 7. Convenient and quick in inquiring measurement data
  • 8. USB data upload
  • 9. Optional: printing

Performance:

Sp02 monitoring

Continuous real-time measuring.Adopt digital Sp02 technology, which has strong anti-interference capability.Real-time display Sp02, pulse rate, Sp02 Plethysmogram, bar graph, Sp02 and Pulse rate(PR) trend graph. Trend graph with the function of adaptive scaling Standard adult finger-clip probe, binding probe for neonatal is optional.

Sp02 Measuring

Range: 35%~100% (Resolution: 1%) Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.

Pulse Rate Measuring

Range: 30bpm~250bpm(Resolution: 1bpm)

Accuracy: ±2bpm or ±2%, whichever is greater.

Measurement Performance in Weak Filling Condition: Sp02 and pulse rate can be shown

correctly when pulse-filling ratio is 0.4%, Sp02 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.

Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darKroom is less than ±1%.


POX-710

  • 7" Colur TFT Display, led backlight , 800x600 pixels.Operating Mode Selection: Neonatal/Pediatric/Adult.
  • Visual and Audio alarms, adjustable.
  • Patient management, name and age and id.
  • Network with Central Station Software,
  • Built-in removable and rechargeable lithium battery,
  • easy operating UI with both Keypad menu.
  • Powerful data storage and managment, Trend graph, Trend table, etc
  • Arrythmia analysis and S-T segment analysis.

Standard parameters:

NIBP, SPO2 , PR

Optional:

EtCO2 , Touchscreen , Thermal Recorder

NIBP

Method Oscillometric

Mode Manual, Auto, Start

Interval in auto mode

1,2,3,4,5,10,15,30,60,90,120,180,240 & 480mints

Accuracy Max Mean Error : +/- 5mmHg

Alarm type

SYS, DIAS & MEAN, : SYS: 40-275 mmHg,

DIAS:10-215 mmHg, Mean :20- 165 mmHg

SpO2

Measuring Range 1-100%

ALARM RANGE 0-100%

Resolution 1%

AVERAGING 4, 8 & 16 seconds

ALARM DISPLAY 10 seconds

PULSE RATE & ALARM 25-240BPM

RESOLUTION 1 BPM

ACCURACY + / - 2BPM

+ / - 2% - 70% - 100%

Pulse Rate

SourceUser Slectable: Smart,ECG,Pleth,NIBP

Range Adult 15-300 bpm

Pediatric 15-350 bpm

Accurancy ±1bpm or ±1% whichever is greate

Printer (optional)

Type Thermal printer

Paper Speed 25 or 50 mm/sec

Trends

Memory

96 hr at 30 second intervals for a NIBP reading every 5 mintues

Display trabular;graphical

Physically

Power Source 110V-240V, 50/60Hz

Weight Approximate 1.7 Kg

Audio volume ajustable 1 ~4 level