Cardiac Care & ICU Equipments

ECG Machines
   - 3-Channel ECG Machine
   - 6-Channel ECG Machine
   - 12-Channel ECG Machine
   - ECG Simulator

Oxygen Analyser
   - Oxygen Analyser SmartO2 830
   - Oxygen Analyser Model Oxiquant MC
Defibrillator
   - AED
   - AED Trainer
   - Biphasic Defibrillator Rescue 230
   - Biphasic Defibrillator Rescue Life

Multipara Monitor
   - 2 - Para Monitor
   - 5 - Para Monitor

   - External Sidestream ETCO2
   - Mainstream End Tidal
     CO2 Sensor

Non Invasive B.P. Monitor
Infusion Pump
   - Syringe Infusion Pump
   - Volumetric Infusion Pump
   - Portable Syringe Pump
Pulse Oximeter
   - Fingertip Pulse Oximeter
   - Handheld Pulse Oximeter
   - Tabletop Pulse Oximeter
Vascular Doppler
Holters
   - 12-Channel Holter
   - 3-Channel Holter

Connect with us:  

Contact me now: 
sales@medicalpointindia.com
medical_point 
hygeiamed@hotmail.com 
medical_point
 

3-Channel Holter
TLC9803 Dynamic ECG Systems

Introduction
Dynamic ECG Systems adopt 3-lead, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community. 

Main Features

  1. The recorder can real-time store ECG data for 24-hour.
  2. Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
  3. With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
  4. Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
  5. Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
  6. All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function. 
  7. With many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
  8. Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
  9. With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability.
  10. One-key print, convenient and fast to print the reports.
  11. Perfect case management function.
  12. The risk of sleep breath pause can be predicted by the unique "Sleep breath pause syndrome"analysis function.
  13. )The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
  14. “T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death

 

 

 ęCopyright MEDICAL POINT, Delhi (India) All rights reserved throughout the World Site Designed & Maintained by mark design