Emergency call : +91-11-43629200, 23289200
  • Medical Point

    Enquiry

DIGITAL THREE CHANNEL ELECTROCARDIOGRAPH

  • Compact in size, easy and direct operation, portable
  • Multiple operation modes : Manual/Auto/Arrhymia Analysis Modes
  • 12-lead ECG simultaneous acquisition
  • 480 x 272 graphic 4.3 inch color screen
  • 80mm, 3 channel recording with a rhythm lead
  • Adapt to 110-230V, 50/60Hz AC power supply
  • 800 x 480 graphic 3.5 inch color LCD
  • Built-in rechargeable Li-ion battery, 3 hours continuous working
  • 250 patients information storage
  • Built in USB/RS232 interface
  • Digital filters eliminate EMG, AC, Baseline Drift interference
Lead Standard 12 leads

Lead

Standard 12 leads

Lead acquisition

12bit/l000Hz (synchronously 12 leads)

Work mode

Manual/ Auto / Physical Examination / Storage

Filter

- AC Filter: 50Hz / 60Hz

• EMG Filter: 25Hz / 45Hz

• Anti-Drift Filter: 0.15Hz (Adaptive)

CMMR

≥1OOdB (with AC Filter)

Input circuit

Floating; Protection circuit against

Defibrillator effect

Input impedance

≥50MΩ

Input circuit current

≤0.05µA

Patient current leakage

<10µA

Calibrating voltage

1mV± 3%

Voltage tolerance

≥±500mV

Time constant

≥3.2s

Frequency response

0.05~160Hz (-3db)

Noise level

< 15µVp-p

Inter-channel interference

≤0.5mm

Sensitivity

2.5, 5, 10, 20mm{mv ±3%

Recording mode

• 1ch. 1ch+

• Default Man. Mode is 1ch format

• Default Auto. Mode is 1ch+ format

Paper speed

6.25. 12.5, 25, 50mm/s (±3%)

Paper

50mm x 20m Roll Paper

Communication

RS232/ USB port

Power supply

• AC 110-230V (±10%), 50/60HZ (±1Hz). 30VA

• DC Built-in rechargeable battery. 12V (1500mmAh)

Dimension / Weight

300mm x 230mm x 75mm / 2.8Kg

Three Channel Electrocardiograph

FUNCTION

  • Compact in size, easy and direct operation, portable
  • Accurate pace pulse identification and automatic analysis function
  • Four working modes: Manual/ Auto/ R-R Analysis / Storage
  • 12 leads simultaneous waveforms display
  • 80mm single channel format recording
  • Advanced [Freeze] function
  • 800x480 graphic 3.5 inch color LCD
  • Built-in USB, RS232 interface, ECGNET software optional
  • Built-in rechargeable Ni-MH battery
  • 100 patients information storage (Extendable)
  • USB interface allows net transmission,USB flash disk and USB printer connected (Optional)
Lead Standard 12 leads
Load Acquisition 12bit/1000Hz (synchronously 12 leads)
Work mode Manual / Auto / Physical Examination / Storage
Filter AC Filter: 50Hz / 60Hz
EMG Filter :25Hz/45Hz
Anti-Drift Filter: 0.15Hz (Adaptive)
CMMR ?100dB (with AC Filter)
Input circuit Floating; Protection circuit against
Defibrillator effect
Input impedance ≥50MΩ
Input circuit current ≥0.05µA
Patient current leakage ≤10µA
Calibrating voltage 1mV±2%
Voltage tolerance ≥500mV
Time constant ≥3.2s
Frequency response 0.05~160 Hz (-3db)
Noise level <15µVp-p
Inter-channel interference ≥0.5mm
Sensitivity Auto, 2.5, 5, 10, 20. 40mm/mV
Recording mode 3ch, 3ch+
Default Man. Mode is 3ch format
Default Auto.Mode is 3ch+ format
Paper speed 6.25, 12.5, 25, 50mm/s (±3%)
Paper 80mm x 20m Roll Paper
Communication RS232/ USB port
Power supply AC 110-230V (±10%), 50/60HZ (±1Hz), 60VA
DC Built-in rechargeable battery. i4.4V(2000mmAh)
Dimension / WeightWeight 300mm x 230mm x 75mm / 2.8Kg